This chapter includes the following sections:
Overview
This guide contains information and procedures for installing Cisco UCS Rack Mount Servers for integration with Cisco UCS Manager.
Cisco UCS C-Series Rack-Mount Servers are managed by the built-in standalone software, Cisco Integrated Management Controller (CIMC) . When a C-Series Rack-Mount Server is integrated with Cisco UCS Manager, the Cisco IMC does not manage the server anymore. Instead it is managed with the Cisco UCS Manager software. You will manage the server using the Cisco UCS Manager GUI or Cisco UCS Manager CLI.
![]() Important | If your server is not new, make sure to reset the Cisco IMC to factory default settings before integrating the server with Cisco UCS Manager. See Server Utilities chapter in Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide for your release to reset the server to factory default settings. |
You can integrate Cisco UCS C-Series Rack-Mount Servers with Cisco UCS Manager in either one of the following setup:
-
Cluster setup: Using two Fabric Interconnects (FIs) or two FIs with two Fabric Extenders (FEXes) to connect the C-Series Rack-Mount Server.
-
Non-cluster setup: Using a single Fabric Interconnect or one FI with one FEX to connect the C-Series Rack-Mount Server. Cisco does not recommend operating UCS domains in Non-Cluster mode because of lack of resiliency. Complete domain outage is expected during routine maintenance upgrades.
![]() Note | For Cisco UCS C-Series Rack-Mount Servers integration with Cisco UCS Manager, Cisco VIC adapters can only be connected to Cisco UCS Fabric Interconnects and not to third-party switches. |
For Cisco UCS S-Series Rack-Mount Servers integration with Cisco UCS Manager, see the Cisco UCS S3260 Server Integration with Cisco UCS Manager guide in your specific release.
Integrating C-Series Rack Mount Server with Cisco UCS Manager
Cisco UCS Manager provides three connectivity modes for Cisco UCS C-Series Rack-Mount Server management. The following are the connectivity modes:
-
Direct Connect Mode: In this mode, a Cisco UCS VIC from a C-Series Rack-Mount Server connects directly to the Fabric Interconnect. Both management and data traffic pass through from the VIC to FI and vice versa.
-
SingleConnect (Sideband): In this mode, a Cisco UCS VIC from a C-Series Rack-Mount Server connects to FEX and then the Fabric Interconnect. Both management and data traffic pass from VIC to FEX and FI.
-
Dual-wire Management (Shared LOM): In this mode, shared LAN on the Motherboard (LOM) port from a C-Series Rack-Mount Server connects to FEX for the management traffic. Cisco UCS VIC connects to the FI for the data traffic.
![]() Note | Cisco UCS C125 M5 Serversdo not contain any LOM ports. |
The general prerequisites for Dual-wire integration with Cisco UCS Manager are built into the C-Series Rack-Mount Server CIMC release 1.4(6) or later. If you want to use the SingleConnect or direct connect modes you must have the following:
-
Cisco UCS VIC 1225 Virtual Interface Card
-
Cisco UCS VIC 1227 (MLOM)
-
Cisco UCS VIC 1225T Virtual Interface Card
-
Cisco UCS VIC 1227T (MLOM)
-
Cisco UCS VIC 1387 (MLOM)
-
Cisco UCS VIC 1385
-
Cisco UCS VIC 1455 (supported in M5 and M6 Servers)
-
Cisco UCS VIC 1457 (MLOM) (supported only in C220 M5 and C240 M5 servers)
-
Cisco UCS VIC 1495 (supported in M5 and M6 Servers)
-
Cisco UCS VIC 1497 (MLOM) (supported only in C220 M5 and C240 M5 servers)
![]() Note | For latest support matrix, refer Release Notes for Cisco UCS Manager, Release 4.2.
|
The following table lists the C-Series Rack-Mount Servers and supported management options:
![]() Note | Dual-Wire Management is supported only with Cisco VIC adapters and not with third-party adapters. |
Servers | SingleConnect | Direct Connect Mode | Dual-wire Management |
---|---|---|---|
Cisco UCS C22 M3 Server | Yes | Yes | Yes |
Cisco UCS C24 M3 Server | Yes | Yes | Yes |
Cisco UCS C220 M3 Server | Yes | Yes | Yes |
Cisco UCS C240 M3 Server | Yes | Yes | Yes |
Cisco UCS C420 M3 Server | Yes | Yes | Yes |
Cisco UCS C220 M4 Server | Yes | Yes | Yes |
Cisco UCS C240 M4 Server | Yes | Yes | Yes |
Cisco UCS C460 M4 Server | Yes | Yes | Yes |
Cisco UCS C240 SD M5 Server | Yes | Yes | Yes |
C480 M5 and C480 M5 ML servers | Yes | Yes | Yes |
Cisco UCS C125 M5 Server | Yes | Yes | No |
Based on your server model and CIMC version, you can use either one of these three integration options to connect the rack server with Cisco UCS Manager.
Cisco UCS Manager runs within the fabric interconnect (FI). With earlier Cisco UCS Manager releases, you need to use Fabric Extenders to connect the C-series server with the Fabric Interconnect to enable management with Cisco UCS Manager. You can directly connect the server adapter with the Fabric Interconnect without using the Fabric Extender.
You can use any of the interfaces available with this management service to access, configure, administer, and monitor the network and server resources for all chassis connected to the fabric interconnect. For information about the Cisco UCS 6400 Series Fabric Interconnect, Cisco UCS 6300 Series Fabric Interconnect, or Cisco UCS 6200 Series Fabric Interconnect, see the documentation at the following links:
-
Cisco UCS 6500 Series Fabric Interconnect documentation
-
Cisco UCS 6400 Series Fabric Interconnect documentation
-
Cisco UCS 6300 Series Fabric Interconnect documentation
-
Cisco UCS 6200 Series Fabric Interconnect documentation
For information about the Cisco Nexus 2232PP, Cisco Nexus 2232TM-E or Cisco Nexus 2348UPQ fabric extenders (FEXes) in the configuration, see the documentation at the following link:
-
Cisco Nexus 2000 Series Fabric Extender documentation
Hardware Maintenance
Replacing servers and certain adapter cards requires that the server be decommissioned and recommissioned. See the decommissioning a Rack-Mount server and recommissioning a Rack-Mount Server sections in the appropriate Cisco UCS Manager Configuration Guide.
FEX Connection Mode and Discovery
You can connect the FEX to the FI in two ways. Cisco UCS Manager FI discovers the FEX based on the FEX/Chassis discovery mode. The FEX connection modes are:
-
Hard-Pinning mode: The server facing FEX ports are pinned to the connected uplink ports when the FEX is discovered. Cisco UCS Manager pins the server-facing ports to the uplink ports based on the number of acknowledged uplink ports. After the pinning, if you add a new uplink or delete an existing uplink, you must manually acknowledge the FEX to apply the changes.
-
Port-Channel mode: Port-Channel mode does not have pinning. A single port channel works as the uplink to all server-facing ports. And all uplink ports are members of this single port channel. If one of the uplink ports goes down, the traffic is automatically distributed to another available uplink port.
In port-channel mode, when you cable between FEX and the FI, the available virtual interface (VIF) namespace varies, depending on where the uplinks are connected to the FI ports:
-
When port-channel uplinks from the FEX are connected only within a set of eight ports managed by a single chip, Cisco UCS Manager maximizes the number of VIFs used in service profiles deployed on the servers.
-
If uplink connections are distributed across ports managed by separate chips, the VIF count is decreased. For example, if you connect seven members of the port channel to ports 1–7, but the eighth member to port 9, this port channel can only support VIFs as though it had one member.
![]() Note |
|
For more information on FEX discovery policies and port-channel allocation, see the appropriate Cisco UCS Manager Configuration Guide.
Maximum Configurable vNICs/vHBAs Based on Number of FEX Uplinks
The following table describes maximum configurable vNICs/vHBAs on a VIC adapter based on the number of FEX uplinks:
Acknowledged link between FEX and FI | Maximum configurable vNICs/vHBA on a VIC adapter for the VIC adapters 1225, 1225T, 1227, 1227T, 1385, 1387, 1455, 1457 |
---|---|
1 | 116 |
2 | 116 |
4 | 116 |
8 | 116 |
16 | 116 |
Acknowledged link between FEX and FI | Maximum configurable vNICs/vHBA on a VIC adapter for the VIC adapters 1225, 1225T, 1227, 1227T, 1385, 1387, 1455, 1457, 1495, and 1497 |
---|---|
1 | 116 |
2 | 116 |
4 | 116 |
8 | 116 |
Acknowledged link between FEX and FI | Maximum configurable vNICs/vHBA on a VIC adapter for the VIC adapters 1225, 1225T, 1227, 1227T, 1385, 1387, 1455, 1457, 1495, and 1497 |
---|---|
1 | 12 |
2 | 27 |
4 | 57 |
8 | 116 |
New Hardware
New Hardware in Release 4.1(2b)
Peripherals
-
Support for RAID controller on Cisco UCS C240 SD M5 Server.
New Hardware in Release 4.1(2a)
Server
-
Cisco UCS C240 SD M5 Server
Peripherals
-
Support for Mellanox ConnectX-5 MCX516A-CDAT dual port 100GbE QSFP28 NIC (UCSC-P-M5D100GF) on Cisco UCS C220 M5, C240 M5 and S3260 Storage servers
-
Support for UCSC-GPU-RTX6000 and UCSC-GPU-RTX8000 on Cisco UCS C240 M5 servers.
-
Support for Cisco 9400-8I 12G SAS HBA (UCSC-9400-8I) on Cisco UCS C125 M5 servers.
-
Cisco UCS C4200 Series Rack Server Chassis—is a modular, dense rack server chassis that supports up to four Cisco UCS C125 M5 Rack Server Nodes, optimized for use in environments requiring dense compute form factor and high core densities such as scale-out/compute intensive, general service provider, and bare-metal applications.
-
Support for Cisco UCS C125 M5 Rack Server Node based on AMD EPYC 2 7002 (ROME) Processors.
-
Support for the following NVMe drives on Cisco UCS S3260 Storage servers:
NVMe Drive
PID for UCS S3260
Product Description
SN640 1.9TB
UCS-S3260-NVMW19T
1.9TB 2.5 in U.2 WD SN640 NVMe Med. Perf. Value Endurance
SN640 6.4TB
UCS-S3260-NVMW64T
6.4TB 2.5 in U.2 WD SN640 NVMe Med. Perf. Value Endurance
New Hardware in Release 4.1(1a)
Fabric Interconnect
-
Cisco UCS 64108 Fabric Interconnect
Peripherals
Support for the following Network Interface Cards on UCS C125 M5 servers:
-
Intel X710 4-Port 10GbE (UCSC-PCIE-IQ10GF)
-
Intel XXV710-DA2OCP1 2 Port x 10/25Gb OCP 2.0
-
Intel X710-DA2 2 x 10GbE SFP+ PCIe
Support for Mellanox ConnectX-5 MCXM516A-CDAT 2 x 100GbE QSFP PCI NIC (UCSC-P-M5D100GF) on C220 M5, C240 M5, C480 M5, C480 M5 ML servers
Support for the following Mellanox adapters on C220 M5, C240 M5, C480 M5 servers:
-
Mellanox ConnectX-5 MCX515A-CCAT 1 x 100GbE QSFP PCI NIC (UCSC-P-M5S100GF)
-
Mellanox ConnectX-5 EN MCX512A-ACAT 2 x 25Gb/10GbE SFP PCI NIC (UCSC-P-M5D25GF)
Support for the QLogic QLE 2692 - 2 x 16Gb Gen 6 Fibre Channel HBA on UCS C125 M5 servers
Support for the following NVME drives on UCS C125 M5 servers:
NVMe Drive | PID for UCS C125 M5 |
---|---|
Intel P4510 1TB (SSDPE2KX010T8K) | UCSC-NVME2H-I1000 |
Intel P4510 4TB (SSDPE2KX040T8K) | UCSC-NVME2H-I4000 |
Intel P4610 1.6TB (SSDPE2KE016T8K) | UCSC-NVME2H-I1600 |
Intel P4610 3.2TB (SSDPE2KE032T8K) | UCSC-NVME2H-I3200 |
Supported C-Series Servers and Adapter Cards
Adapter Cards
The following table shows the supported adapter cards for C-Series Rack-Mount Servers integration with Cisco UCS Manager:
Adapter Model | Dual-Wire Connection | SingleWire Connection | Direct Connection |
---|---|---|---|
Cisco UCS VIC 1495 (UCSC-PCIE-C100-04) | No | No | Yes |
Cisco UCS VIC 1497 (UCSC-MLOM-C100-04) | No | No | Yes |
Cisco UCS VIC 1467 (UCSC-M-V25-04) | Yes | Yes | Yes |
Cisco UCS VIC 1477 (UCSC-M-V100-04) | No | No | Yes |
Cisco UCS VIC 1455 (UCSC-PCIE-C25Q-04) | Yes | Yes | Yes |
Cisco UCS VIC 1457 (UCSC-MLOM-C25Q-04) | Yes | Yes | Yes |
Cisco UCS VIC 1387 (UCSC-MLOM-C40Q-03) | Yes | Yes | Yes |
Cisco UCS VIC 1385 (UCSC-PCIE-C40Q-03) | Yes | Yes | Yes |
Cisco UCS VIC 1227T (UCSC-MLOM-C10T-02) | Yes | Yes | No |
Cisco UCS VIC 1227 UCSC-MLOM-CSC-02 | Yes | Yes | Yes |
Cisco UCS VIC 1225 (UCSC-PCIE-CSC-02) | Yes | Yes | Yes |
Cisco UCS VIC 1225T (UCSC-PCIE-C10T-02) | Yes | Yes | No |
QLogic QL45412H 40GbE1 (UCSC-PCIE-QD40GF) | Yes | No | No |
![]() Note | Dual-wire management is not supported on the following:
|
![]() Note | Different generation VIC adapters are not supported in a single server. For example, if a server has two VIC cards, both these VIC adapters should be either 1400 series or 1300 series or 1200 series. Cisco UCS 15000 Series VIC adapters can be mixed with 1400 series VIC adapters in M6 rack servers. For example, the VIC 15428 MLOM could be used along with 1455/1495 VIC adapter in an M6 rack-server. |
![]() Note | For rack server and adapter compatibility, see the respective rack server spec sheet. For connectivity options with Cisco UCS Manager, see Configuration Guides. |
Cisco UCS Manager Upgrade Consideration
Beginning with Cisco UCS Manager 3.2(2b) release, UCS Manager does not allow provisioning any vNICs or vHBAs on adapters not listed in in Table 1.
Network Topology and Supported Cables
The following image is a graphical representation of the over-all network topology supported in the C-Series server integration with Cisco UCS Manager.
![Cisco UCS C-Series Server Integration with Cisco UCS Manager 4.1 - Cisco UCS C-Series Integration with Cisco UCS Manager [Cisco UCS C-Series Rack-Mount UCS-Managed Server Software] (10) Cisco UCS C-Series Server Integration with Cisco UCS Manager 4.1 - Cisco UCS C-Series Integration with Cisco UCS Manager [Cisco UCS C-Series Rack-Mount UCS-Managed Server Software] (10)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/300001-310000/306001-307000/306920.jpg)
![Cisco UCS C-Series Server Integration with Cisco UCS Manager 4.1 - Cisco UCS C-Series Integration with Cisco UCS Manager [Cisco UCS C-Series Rack-Mount UCS-Managed Server Software] (11) Cisco UCS C-Series Server Integration with Cisco UCS Manager 4.1 - Cisco UCS C-Series Integration with Cisco UCS Manager [Cisco UCS C-Series Rack-Mount UCS-Managed Server Software] (11)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/400001-500000/450001-460000/453001-454000/453136.jpg)
For more information on server, Cisco VIC and FEX/IOM compatibility, refer Cisco UCS Fabric Interconnect Server Compatibility Matrix - Release 4.2(3) section in Release Notes for Cisco UCS Manager, Release 4.2.
![]() Note | In Cisco UCS Manager, Cisco UCS 6332 and 6332-16UP Fabric Interconnects are supported. Cisco UCS 6324 Fabric Interconnect is not supported. For Cisco UCS 6200 Fabric Interconnects, the Cisco UCS C220 M6 and C240 M6 servers are not supported in Cisco UCS Manager even if VIC 1455 or 1457 are used. |
The thick blue line represents a 40 Gigabit Ethernet connection, the thin line represents a 10 Gigabit Ethernet connection. 40 Gigabit Ethernet connections are supported on the Cisco VIC 1385, 1387, 1477, , 1495, and 1497 adapters. 10 Gigabit Ethernet connections are supported on the Cisco VIC 1225, 1227 1385, 1387, 1455, 1457, and 1467 adapters. 25 Gigabit Ethernet connections are supported only on the Cisco VIC 1455, 1457, and 1467.
For the 10 Gigabit Ethernet, the following cables are used:
-
4x10 Breakout Small Form-Factor Pluggable (SFP) cables
-
4x10 Active Optical (OAC) cables
-
10G Small Form-Factor Pluggable (SFP) cable that uses the Qualified Security Assessor (QSA) module
For the 25 Gigabit Ethernet, the following cables are used:
-
25G SFP 28
![]() Note | While using Cisco VIC 1385 and 1387 in a 10G connection you would a require a 40G to 10G QSFP convertor and you cannot use the 4x10 Breakout Small Form-Factor Pluggable (SFP) cables or 4x10 Active Optical (OAC) cables. Break-out is not supported from VIC when connecting towards FI or FEX. Break-out cables are supported from FI towards VIC 1225/1227 and VIC 1455/1457. |
The 6400, 6300, and 6200 Series FIs can be connected to Cisco VIC adapters and FEXs as shown in the table below.
Cisco UCS 6400 Series Fabric Interconnect | Cisco VIC 1385, 1387, 1455, 1457, or 1467 | ||
Cisco UCS 6400 Series Fabric Interconnect with Cisco Nexus 2232PP FEX | Cisco VIC 1385, 1387, 1455, 1457, or 1467 (10 G link) | ||
Cisco UCS 6300 Series FI (63xx) | Cisco VIC 1385, 1387, 1455, 1457, 1467, 1477, 1495, or 1497 | ||
Cisco UCS 6300 Series FI (63xx) with Cisco Nexus 2232PP (4x10 G breakout cable) or 2348UQ (40 G link) | Cisco VIC 1385, 1387, 1455, 1457, or 1467 (10 G link) | ||
Cisco UCS 6200 Series FI (62xx) with Cisco Nexus 2232PP | Cisco VIC 1385, 1387, 1455, or 1457 | ||
Cisco UCS 6200 Series FI (62xx) | Cisco Nexus 2232PP Cisco VIC 1385, 1387, 1455, or 1457 (10 G link)
|
![]() Note | Cisco C-Series servers cannot be integrated with Cisco UCS Manager using a combination of Cisco UCS 6324 Fabric Interconnect and Cisco UCS VIC 1400. |
FI / 10G Rack VIC / Connector | VIC 1225 | VIC 1227 | ||||||
---|---|---|---|---|---|---|---|---|
10 G | QSA | 40 G | Breakout Cable | 10 G | QSA | 40 G | Breakout Cable | |
FI 62xx | Yes | NA | NA | NA | Yes | NA | NA | NA |
FI 6324 | Yes | NA | NA | Yes (4x10 fabric ports only) | Yes | NA | NA | Yes (4x10 fabric ports only) |
FI 6332 | NA | Yes | NA | Yes (4x10 fabric ports only) | NA | Yes | NA | Yes (4x10 fabric ports only) |
FI 6332-16UP | Yes | Yes | NA | Yes (4x10 fabric ports only) | Yes | Yes | NA | Yes (4x10 fabric ports only) |
Cisco UCS 6400 Series Fabric Interconnect | Yes | NA | NA | NA | Yes | NA | NA | NA |
FI / 40G Rack VIC / Connector | VIC 1385 | VIC 1387 | ||||||
---|---|---|---|---|---|---|---|---|
QSA | 40 G | Breakout Cable | QSA | 40 G | Breakout Cable | |||
FI 62xx | Yes | NA | NA | Yes | NA | NA | ||
FI 6324 | Yes | NA | NA | Yes | NA | NA | ||
FI 6332 | Yes | Yes | NA | Yes | Yes | NA | ||
FI 6332-16UP | Yes | Yes | NA | Yes | Yes | NA | ||
Cisco UCS 6400 Series Fabric Interconnect | Yes | NA | NA | Yes | NA | NA |
FI / 10G Rack VIC / Connector | VIC 1455 , 1457, and 1467 | |||
---|---|---|---|---|
10 G | QSA | 25 G | Breakout Cable | |
FI 62xx | Yes (not supported with 1467) | NA | NA | NA |
FI 6324 | NA | NA | NA | NA |
FI 6332 | NA | NA | NA | Yes |
FI 6332-16UP | Yes | NA | NA | Yes |
Cisco UCS 6400 Series Fabric Interconnect | Yes | NA | Yes | Yes (from Cisco UCS Manager, Release 4.1(3) |
FI / 40G Rack VIC / Connector | VIC 1477, VIC 1495, and VIC 1497 | ||
---|---|---|---|
QSA | 40G | Breakout Cable | |
FI 62xx | NA | NA | NA |
FI 6324 | NA | NA | NA |
FI 6332 | NA | Yes | NA |
FI 6332-16UP | NA | Yes | NA |
Cisco UCS 6400 Series Fabric Interconnect | NA | NA | NA |
Supported RAID/Storage Controller Configurations
Only servers without expanders can have more than one RAID controllers in the Cisco UCS Manager integrated mode. The following servers are allowed to have more than one RAID controllers in the Cisco UCS Manager integrated mode:
-
Cisco UCS C24 M3 (UCSC-C24-M3S2)
-
Cisco UCS C420 M3 (UCSC-C420-M3)
-
Cisco UCS C240 M3 (UCSC-C240-M3S2)
-
Cisco UCS C240 M3 NEBS (UCSC-C240-SNEBS)
-
Cisco UCS C220 M4 (UCSC-C220-M4)
-
Cisco UCS C240 M4 (UCSC-C240-M4)
-
Cisco UCS C460 M4 (UCSC-C460-M4)
-
Cisco UCS C240 M5 (UCSC-C240-M5L)
-
Cisco UCS C240 M5 (UCSC-C240-M5S)
-
Cisco UCS C240 M5 (UCSC-C240-M5SX)
-
Cisco UCS C240 M5 (UCSC-C240-M5SN)
-
Cisco UCS C240 SD M5 (UCSC-C240-M5SD)
-
Cisco UCS C220 M5 (UCSC-C220-M5L)
-
Cisco UCS C220 M5 (UCSC-C220-M5SX)
-
Cisco UCS C220 M5 (UCSC-C220-M5SN)
-
Cisco UCS C480 M5 (UCSC-C480-M5)
-
Cisco UCS C480 M5 ML Server (USC-C480-M5ML)
![]() Note | Cisco UCS C125 M5 Servers do not support multiple PICe RAID controllers. There are only 2 PCIe slots; one for a VIC card and the other for a RAID controller. |
Any server not on this list that has more than one RAID controller installed, fails discovery.
The following RAID/Storage controllers are supported for C-Series rack-mount servers integration with Cisco UCS Manager.
![]() Note | A fully loaded LSI controller supports RAID 0, 1, 5, 50, 6, 10 and 60. If you remove a memory card from an LSI controller, UCS Manager cannot create RAID 6 and 10. |
Server | Supported Storage Controller | ||||
---|---|---|---|---|---|
Cisco UCS C240 M3 (UCSC-C240-M3) |
| ||||
Cisco UCS 220 M3 (UCSC-C220-M3) |
| ||||
Cisco UCS 22 M3 (UCSC-C22-M3) |
| ||||
Cisco UCS C24 M3 (UCSC-C24-M3) |
| ||||
Cisco UCS C240 M4 (UCSC-C240-M4) |
| ||||
Cisco UCS C220 M4 (UCSC-C220-M4) |
| ||||
Cisco UCS C460 M4 (UCSC-C460-M4) |
| ||||
Cisco UCS C220 M5 (UCSC-C220-M5SX) |
| ||||
Cisco UCS C220 M5 (UCSC-C220-M5L) |
| ||||
Cisco UCS C220 M5 (UCSC-C220-M5SN) |
UCSC-C220-M5SN does not support embedded RAID. | ||||
Cisco UCS C240 M5 (UCSC-C240-M5S) |
| ||||
Cisco UCS C240 M5 (UCSC-C240-M5L) |
| ||||
Cisco UCS C240 M5 (UCSC-C240-M5SX) |
| ||||
Cisco UCS C240 M5 (UCSC-C240-M5SN) |
UCSC-C240-M5SN does not support embedded RAID. | ||||
Cisco UCS C240 SD M5 (UCSC-C240-M5SD) |
| ||||
Cisco UCS C480 M5 (UCSC-C480-M5) |
| ||||
Cisco UCS C125 M5 Server (UCSC-C125) |
| ||||
Cisco UCS C480 M5 ML Server (USC-C480-M5ML) |
|
Supported FlexFlash Configuration
Some Cisco UCS C-Series Rack-Mount Servers support an internal Cisco FlexFlash Secure Digital (SD) memory card for storage of server software tools and utilities. FlexFlash is disabled by default. You can enable FlexFlash in a local disk policy used in a service profile.
![]() Note | Cisco UCS C-Series standalone servers with Cisco FlexFlash SD memory cards configured in Utility mode are not supported in the Cisco UCS Manager Integrated mode. |
After upgrading CIMC if you are unable to install Cisco FlexFlash, apply the scrub policy before configuring the FlexFlash SD cards.
The FlexFlash SD cards can also be scrubbed using the format SD cards option, if the controller supports the same.